Jiangsu Acrel Electrical Manufacturing Co.,Ltd
PRODUCTS CENTER
AKH-0.66/K-Φ 1/5A Split Core Current Transformer UL Certificate
● Split core current transformer ● Accuracy: class 0.5 ● Suitable for electricity renovation project Standards IEC/EN61869-1, IEC/EN61869-2 UL CERTIFICATE
AKH-0.66/K-Φ Series 333mV Split Core Current Transformer
● Split core current transformer ● Accuracy: class 0.5 ● Suitable for electricity renovation project Standards IEC/EN61869-1, IEC/EN61869-2
AHKC-EKA Split Core Hall sensor
Measurement AC, DC, pulse and other complex current Appearance - Small package size - Low power consumption - Extended measuring range
AHKC-E Closed Hall Current Sensor
Measurement AC, DC, pulse and other complex current Rated current input:0-(100-2000)A Rated output: 5V/4V/4-20mA Aperture: 20mm/40mm/60mm/etc Power supply: ±15V / 12V / 24V
AHLC-LTA Closed Loop Hall Current Sensor
Measurement DC, pulse and other complex current Model: AHLC-LTA / AHLC-EA / AHLC-EB Rated current input:10mA-2A Rated output: 5V Power supply: ±15V
AHBC-LTA Closed Loop Hall Current Sensor
Measurement AC, DC, pulse and other complex current Rated current input:0-(100-2000)A Rated output: 50mA/100mA/200mA/400mA Aperture: 20mm/40mm/60mm/etc Power supply: ±15V / 12V / 24V
AKH-0.66/K-Φ Series 400/20mA Split Core Current Transformer
● Split core current transformer ● Accuracy: class 0.5 ● Suitable for electricity renovation project Standards IEC/EN61869-1, IEC/EN61869-2 UL Certificate
AKH-0.66/K Series Open Type Current Transformer
● Split core current transformer ● Easy to install without power off ● Suitable for electricity renovation project Standards IEC/EN61869-1, IEC/EN61869-2
AKH-0.66/I Series Current Transformer
● Current transformer for measurement ● Suitable for cables or copper bus ● Used with energy meters or relays Standards IEC/EN61869-1, IEC/EN61869-2
BD-AI Series Single Phase Current Transducer
BD-AI Series Single Phase current Transducer Measurement - AC current - Overload: 1.2 times of rated value - Analog Output DC 0-5V/0-10V/0-20mA/4-20mA
BD-3I3 Series Three Phase Current Transducer
BD-3I3 Series three phase current Transducer Measurement - Three phase current - Overload: 1.2 times of rated value - Analog Output DC 0-5V/0-10V/0-20mA/4-20mA
BD-4E Series Electricity Transducer
BD-4E Series Electricity Transducer Measurement - Voltage\Current\Power\Power factor\Frequency - Overload: 1.2 times of rated value - Analog Output DC 0-5V/0-10V/0-20mA/4-20mA
BD-3P Series Power Transducer
BD-3P Series Electricity Transducer Measurement - Voltage\Current\Power\Power factor\Frequency - Overload: 1.2 times of rated value - Analog Output DC 0-5V/0-10V/0-20mA/4-20mA
BA10-AI/I Current Transducer
Measurement - Direct AC current measurement up to 600A - Overload: 1.2 times of rated value Application - Industrial automation
BA10-AI/V Voltage Transducer
BA50L-AI/I Leakage Current Transducer
Measurement - Input: 0-1A leakage current - Output: DC 4-20mA or DC 0-5V - Measurement of leakage current - Overload: 1.2 times of rated value